Sciact
  • EN
  • RU

Investigation into Cherenkov Light Scattering and Refraction on Aerogel Surface Full article

Journal Nuclear Instruments and Methods in Physics Research Section A
ISSN: 0168-9002
Output data Year: 2017, Volume: 876, Pages: 249-251 Pages count : 3 DOI: 10.1016/j.nima.2017.03.051
Tags Aerogel, Particle identification, Ring imaging Cherenkov counter
Authors Barnyakov A.Yu. 1,2,3 , Barnyakov M.Yu. 1,2,3,5 , Bobrovnikov V.S. 1,2 , Buzykaev A.R. 1,2 , Danilyuk A.F. 2,4 , Katcin A.A. 1,3 , Kirilenko P.S. 2 , Kononov S.A. 1,2,5 , Korda D.V. 1,2,5 , Kravchenko E.A. 1,2 , Kudryavtsev V.N. 1,2 , Kuyanov I.A. 1,2,5 , Onuchin A.P. 1,2,3 , Ovtin I.V. 1,2,3 , Podgornov N.A. 1,2,5 , Predein A.Yu. 4 , Prisekin V.G. 1 , Protsenko R.S. 4 , Shekhtman L.I. 1,2
Affiliations
1 Budker Institute of Nuclear Physics SB RAS, Novosibirsk, Russia
2 Novosibirsk State University, Novosibirsk, Russia
3 Novosibirsk State Technical University, Novosibirsk, Russia
4 Boreskov Institute of Catalysis SB RAS, Novosibirsk, Russia
5 FSBI “SSC RF ITEP” of NRC “Kurchatov Institute”, Moscow, Russia

Funding (2)

1 Council for Grants of the President of the Russian Federation НШ-2479.2014.2
2 Russian Foundation for Basic Research 14-02-00984

Abstract: The work concerns the development of aerogel radiators for RICH detectors. Aerogel tiles with a refractive index of 1.05 were tested with a RICH prototype on the electron beam on the VEPP-4M collider. It has been shown that polishing with silk tissue yields good surface quality, the amount of light loss at this surface being about 5–7%. The Cherenkov angle resolution was measured for a tile in two conditions: with a clean exit face and with a polished exit face. The number of photons detected was 13.3 and 12.7 for the clean and polished surfaces, respectively. The Cherenkov angle resolution for the polished surface is 55% worse, which can be explained with the forward scattering on the polished surface. A tile with a crack inside was also tested. The experimental data show that the Cherenkov angle resolution is the same for tracks crossing the crack area and in a crack-free area.
Cite: Barnyakov A.Y. , Barnyakov M.Y. , Bobrovnikov V.S. , Buzykaev A.R. , Danilyuk A.F. , Katcin A.A. , Kirilenko P.S. , Kononov S.A. , Korda D.V. , Kravchenko E.A. , Kudryavtsev V.N. , Kuyanov I.A. , Onuchin A.P. , Ovtin I.V. , Podgornov N.A. , Predein A.Y. , Prisekin V.G. , Protsenko R.S. , Shekhtman L.I.
Investigation into Cherenkov Light Scattering and Refraction on Aerogel Surface
Nuclear Instruments and Methods in Physics Research Section A. 2017. V.876. P.249-251. DOI: 10.1016/j.nima.2017.03.051 WOS Scopus РИНЦ AN OpenAlex
Dates:
Submitted: Nov 30, 2016
Accepted: Mar 28, 2017
Published online: Mar 29, 2017
Published print: Dec 21, 2017
Identifiers:
Web of science: WOS:000418267300063
Scopus: 2-s2.0-85016577901
Elibrary: 35496516
Chemical Abstracts: 2017:561000
OpenAlex: W2602552691
Citing:
DB Citing
Web of science 1
Scopus 1
Elibrary 1
OpenAlex 1
Altmetrics: