Novel Simplified Absorption-Catalytic Method of Sample Preparation for AMS Analysis Designed at the Laboratory of Radiocarbon Methods of Analysis (LRMA) in Novosibirsk Akademgorodok Научная публикация

Журнал International Journal of Mass Spectrometry (International Journal of Mass Spectrometry and Ion Processes up to 1998)
ISSN: 1387-3806
Вых. Данные Год: 2018, Том: 433, Страницы: 11-18 Страниц : 8 DOI: 10.1016/j.ijms.2018.08.003
Ключевые слова AMS analysis; Biomedical applications; Dating; Sample preparation; Graphitization of CO2; Catalytic combustion; Selective absorbtion of CO2; CaO absorbert
Авторы Lysikov A.I. 1,2 , Kalinkin P.N. 1,2 , Sashkina K.A. 1,2 , Okunev A.G. 1,2 , Parkhomchuk E.V. 1,2 , Rastigeev S.A. 1,3 , Parkhomchuk V.V. 1,3 , Kuleshov D.V. 1,2 , Vorobyeva E.E. 1,2 , Dralyuk R.I. 1,2
Организации
1 Novosibirsk State University, Laboratory of Radiocarbon Methods of Analyses, 2 Pirogova St., Novosibirsk 630090, Russia
2 Boreskov Institute of Catalysis SB RAS, 5 Lavrentieva St., Novosibirsk 630090, Russia
3 Budker Institute of Nuclear Physics SB RAS, 11 Lavrentieva St., Novosibirsk 630090, Russia

Информация о финансировании (1)

1 Федеральное агентство научных организаций России 0303-2018-0008

Реферат: A new absorption-catalytic method of sample preparation for AMS 14C analysis has been designed. The semi-automatic graphitization equipment consists of catalytic combustion, selective absorption/desorption of CO2 and graphitization zones. Sample combustion followed by CO2 separation takes less than 30 min that allows plenty of samples to be processed in a short time. The average CO2 conversion to graphite turned out to be 75%. Achieved value of background induced by contamination with contemporary carbon is about 1.2 pMC. The proposed method is reproducible according to results for the OX-I and OX-II oxalic acid standards measured from 2015 to 2018 and has been successfully used for dating lake sediments. The results agree with the data of other laboratories. The penetration of model aerosol particles inhaled at low dose by mice has been studied by means of the designed method.
Библиографическая ссылка: Lysikov A.I. , Kalinkin P.N. , Sashkina K.A. , Okunev A.G. , Parkhomchuk E.V. , Rastigeev S.A. , Parkhomchuk V.V. , Kuleshov D.V. , Vorobyeva E.E. , Dralyuk R.I.
Novel Simplified Absorption-Catalytic Method of Sample Preparation for AMS Analysis Designed at the Laboratory of Radiocarbon Methods of Analysis (LRMA) in Novosibirsk Akademgorodok
International Journal of Mass Spectrometry (International Journal of Mass Spectrometry and Ion Processes up to 1998). 2018. V.433. P.11-18. DOI: 10.1016/j.ijms.2018.08.003 WOS Scopus РИНЦ CAPlus OpenAlex
Даты:
Поступила в редакцию: 20 апр. 2018 г.
Принята к публикации: 12 авг. 2018 г.
Опубликована online: 13 авг. 2018 г.
Опубликована в печати: 1 окт. 2018 г.
Идентификаторы БД:
Web of science: WOS:000446396300003
Scopus: 2-s2.0-85051637528
РИНЦ: 35730438
Chemical Abstracts: 2018:1569511
OpenAlex: W2885336556
Цитирование в БД:
БД Цитирований
Web of science 18
Scopus 24
РИНЦ 32
OpenAlex 25
Альметрики: