Sciact
  • EN
  • RU

Selection of the Porous Layer Open Tubular Columns for Separation of Light Components in Comprehensive Two-Dimensional Gas Chromatography Full article

Journal Journal of Chromatography A
ISSN: 0021-9673 , E-ISSN: 1873-3778
Output data Year: 2018, Volume: 1579, Pages: 83-88 Pages count : 6 DOI: 10.1016/j.chroma.2018.10.015
Tags Comprehensive two-dimensional gas chromatography; PLOT columns; Porous polymers; Poly-(1-trimethylsilyl-1-propyne); Light components separation; Orthogonality
Authors Patrushev Yuri V. 1,2 , Sidelnikov Vladimir N. 1
Affiliations
1 Boreskov Institute of Catalysis, pr. Lavrentieva 5, Novosibirsk, 630090, Russia
2 Novosibirsk State University, Pirogova Str., 2, Novosibirsk, 630090, Russia

Funding (1)

1 Ministry of Science and Higher Education of the Russian Federation ГЗ-2017-2020

Abstract: Up to the present, comprehensive two-dimensional gas chromatography was commonly performed using combinations of columns with stationary liquid phases. There are singular examples with a porous layer open tubular (PLOT) column used only in the second dimension. However, GC × GC systems with two PLOT columns are not reported in the literature. Our work describes the application of two PLOT columns in the GC × GC mode. In the first and second dimensions we used columns with the sorbents based on organic porous polymers with different selectivity: Rt-Q-BOND (nonpolar column consist of 100% divinylbenzene-styrene), Rt-S-BOND (intermediate polar column, which contain 4-vinylpyridine), Rt-U-BOND (polar column based on divinylbenzene - ethylene glycol dimethylacrylate copolymer), DVB-VIm (divinylbenzene-vinylimidazole copolymer), a column PTMSP with poly-(1-trimethylsilyl-1-propyne) sorbent, and a GASPRO column with porous silica as a stationary phase. The degree of orthogonality was calculated for five different combinations of columns, where a column with the porous polymer was used in the first dimension, and GASPRO column – in the second dimension. Orthogonality was estimated from the correlation coefficient of retention times in the first and second dimensions. Examples of the separation of C1-C5 hydrocarbons on a combination of PTMSP - GASPRO and Rt-Q-BOND - GASPRO columns are reported. It is shown that not only light hydrocarbons but also compounds belonging to different chemical classes can be separated with the use of PLOT columns.
Cite: Patrushev Y.V. , Sidelnikov V.N.
Selection of the Porous Layer Open Tubular Columns for Separation of Light Components in Comprehensive Two-Dimensional Gas Chromatography
Journal of Chromatography A. 2018. V.1579. P.83-88. DOI: 10.1016/j.chroma.2018.10.015 WOS Scopus РИНЦ ANCAN PMID OpenAlex
Dates:
Submitted: Aug 17, 2018
Accepted: Oct 9, 2018
Published online: Oct 10, 2018
Published print: Dec 7, 2018
Identifiers:
Web of science: WOS:000452343700009
Scopus: 2-s2.0-85055180274
Elibrary: 38644544
Chemical Abstracts: 2018:1988166
Chemical Abstracts (print): 170:202435
PMID: 30366693
OpenAlex: W2897721156
Citing:
DB Citing
Scopus 12
Web of science 13
Elibrary 13
OpenAlex 13
Altmetrics: