Sciact
  • EN
  • RU

Lay-Out of Ultrahigh-Vacuum DC-Monochromator Full article

Conference 8th International Conference on Synchrotron Radiation Instrumentation
25-29 Aug 2003 , San Francisco
Source Synchrotron Radiation Instrumentation: Eighth International Conference
Compilation, 2004. ISBN 0-7354-0179-9.
Journal AIP Conference Proceedings
ISSN: 0094-243X , E-ISSN: 1551-7616
Output data Year: 2004, Volume: 705, Pages: 691-694 Pages count : 4 DOI: 10.1063/1.1757890
Authors Zhogin I. 1,2 , Gavrilov N. 2 , Tolochko B. 1 , Ancharov A. 1 , Sharafutdinov M. 1,2 , Kondrat'ev V. 2 , Sheromov M. 2 , Tsukanov V. 2 , Shmakov A. 3
Affiliations
1 Institute of Solid State Chemistry and Mechanochemistry, Russian Federation
2 Institute of Nuclear Physics, Russian Federation
3 Institute of Catalysis, Russian Federation

Abstract: Features and design advantages of the ultra-high vacuum double-crystal monochromator with (practically) fixed exit and the opportunity of sagittal focussing are discussed. Monochromator is projected and is under construction for 6-th synchrotron radiation beamline at VEPP-3 storage ring of Siberian SR center. The first results of testing of monochromator's kinematics are presented as well.
Cite: Zhogin I. , Gavrilov N. , Tolochko B. , Ancharov A. , Sharafutdinov M. , Kondrat'ev V. , Sheromov M. , Tsukanov V. , Shmakov A.
Lay-Out of Ultrahigh-Vacuum DC-Monochromator
In compilation Synchrotron Radiation Instrumentation: Eighth International Conference. 2004. – C.691-694. – ISBN 0-7354-0179-9. DOI: 10.1063/1.1757890 Scopus РИНЦ OpenAlex
Identifiers:
Scopus: 2-s2.0-85012299220
Elibrary: 29484442
OpenAlex: W1642717801
Citing:
DB Citing
Scopus 1
Elibrary 1
Altmetrics: