Sciact
  • EN
  • RU

Dead Volume Determination of the HPLC Monolithic Rod Columns with Organic Sorbents Научная публикация

Журнал Journal of Liquid Chromatography & Related Technologies
ISSN: 1082-6076 , E-ISSN: 1520-572X
Вых. Данные Год: 2019, Том: 42, Номер: 17-18, Страницы: 575-581 Страниц : 7 DOI: 10.1080/10826076.2019.1642917
Ключевые слова HPLC, hydrophilic interaction, monolithic columns, 1-vinyl-1,2,4-triazole, void volume
Авторы Patrushev Yuri 1,2 , Sotnikova Yulia 1,2 , Sidelnikov Vladimir 1
Организации
1 Department of Physicochemical Methods, Boreskov Institute of Catalysis, Novosibirsk, Russia
2 Department of Natural Sciences, Novosibirsk State University, Novosibirsk, Russia

Информация о финансировании (1)

1 Министерство науки и высшего образования Российской Федерации (с 15 мая 2018) ГЗ-2017-2020

Реферат: Features of the dead (void) volume V0 determination of chromatographic columns with organic sorbents were considered. Two monolithic columns were studied: based on divinylbenzene – styrene (DVB-St), and based on 1-vinyl-1,2,4-triazole (VTr). Two methods were used for determination of columns’ void volume: (1) measuring the retention time of unretained components and (2) quantitative determination of the mobile phase (MP) components in the column (direct method). The first method depends on both the component nature and the MP composition, whereas the direct method makes it possible to obtain the void volume value that does not change in a wide range of the MP polarity. For the VTr column, the void volume does not change when the acetonitrile/water MP composition is varied from 100/0 to 20/80. For the DVB-St column, the void volume depends on the MP composition. This occurs due to swelling of the sorbent in a good solvent (high content of acetonitrile) and its shrinking in a poor solvent (high content of water). The absence of the void volume dependence on MP composition for the VTr column can be attributed to 1,2,4-triazole fragments hydrophility. As a result, the monolith is not shrunk at the water excess in the MP.
Библиографическая ссылка: Patrushev Y. , Sotnikova Y. , Sidelnikov V.
Dead Volume Determination of the HPLC Monolithic Rod Columns with Organic Sorbents
Journal of Liquid Chromatography & Related Technologies. 2019. V.42. N17-18. P.575-581. DOI: 10.1080/10826076.2019.1642917 WOS Scopus РИНЦ CAPlus OpenAlex
Даты:
Опубликована online: 26 июл. 2019 г.
Опубликована в печати: 8 нояб. 2019 г.
Идентификаторы БД:
Web of science: WOS:000478331900001
Scopus: 2-s2.0-85073667692
РИНЦ: 41698796
Chemical Abstracts: 2019:1452855
OpenAlex: W2964408348
Цитирование в БД:
БД Цитирований
Web of science 1
Альметрики: