Sciact
  • EN
  • RU

Method for Correction of Experimental Action Spectrum Using Actual Overlapping Spectra of Radiation Sources Научная публикация

Журнал MethodsX
ISSN: 2215-0161
Вых. Данные Год: 2021, Том: 8, Номер статьи : 101221, Страниц : 7 DOI: 10.1016/j.mex.2021.101221
Ключевые слова Photoresponse; Irradiation; Spectra; Basic wavelength; Action spectra
Авторы Lyulyukin Mikhail 1,2,3 , Kovalevskiy Nikita 2,3 , Timofeeva Sofya 2,3 , Gusachenko Egor 2,3 , Solovyeva Maria 2,3 , Selishchev Dmitry 2,3 , Kozlov Denis 2,3
Организации
1 Novosibirsk State Technical University, Novosibirsk 630073, Russia
2 Boreskov Institute of Catalysis, Novosibirsk 630090, Russia
3 Novosibirsk State University, Novosibirsk 630090, Russia

Информация о финансировании (1)

1 Российский фонд фундаментальных исследований 19-33-60019 (АААА-А19-119111890026-5)

Реферат: Experimental dependency of the photosystem's response on the wavelength of exciting radiation, also known as action spectrum, may be substantially affected by the spectrum shape of this radiation. This is especially important in the case, when different radiation sources are used for the investigation of action spectrum. For instance, too wide emission peaks of radiation sources can blur the scopes of actual action spectrum and distort information about the properties of photosystem at certain wavelength regions. Here we propose a method for the correction of experimental action spectrum by the recalculation of experimental data of photoresponse according to actual spectra of exciting radiation. In the case of overlapping radiation spectra from different radiation sources, this method results in much better correlation of experimental action spectrum to actual action spectrum or absorption spectrum of photosystem. The data on photoactivity of several photocatalysts are presented to illustrate and validate the proposed method. • The activity of photosystem depends on the actual spectrum of the radiation source • Single-peak optical radiation sources with the same basic wavelength may cause a different photoactivity • The effect of actual spectrum of the light source on the photoactivity is to be considered
Библиографическая ссылка: Lyulyukin M. , Kovalevskiy N. , Timofeeva S. , Gusachenko E. , Solovyeva M. , Selishchev D. , Kozlov D.
Method for Correction of Experimental Action Spectrum Using Actual Overlapping Spectra of Radiation Sources
MethodsX. 2021. V.8. 101221 :1-7. DOI: 10.1016/j.mex.2021.101221 WOS Scopus РИНЦ PMID OpenAlex
Файлы: Полный текст от издателя
Даты:
Поступила в редакцию: 21 авг. 2020 г.
Опубликована в печати: 1 янв. 2021 г.
Принята к публикации: 4 янв. 2021 г.
Опубликована online: 7 янв. 2021 г.
Идентификаторы БД:
Web of science: WOS:000707188200026
Scopus: 2-s2.0-85099356177
РИНЦ: 45006546
PMID (PubMed): 34434744
OpenAlex: W3119570579
Цитирование в БД:
БД Цитирований
Scopus 2
РИНЦ 1
Web of science 2
OpenAlex 2
Альметрики: