Sciact
  • EN
  • RU

On Reachable Energy Resolution of SiPM Based Scintillation Counters for X-ray Detection Научная публикация

Журнал Journal of Instrumentation
ISSN: 1748-0221
Вых. Данные Год: 2017, Том: 12, Номер: 1, Номер статьи : P01001, Страниц : 14 DOI: 10.1088/1748-0221/12/01/p01001
Ключевые слова Photon detectors for UV, visible and IR photons (solid-state) (PIN diodes, APDs, Si-PMTs, G-APDs, CCDs, EBCCDs, EMCCDs etc); Scintillators, scintillation and light emission processes (solid, gas and liquid scintillators); X-ray detectors
Авторы Kuper K.E. 1 , Oleynikov V.P. 1,2 , Porosev V.V. 1,2 , Savinov G.A. 1 , Drozdowski W. 3
Организации
1 Budker Institute of Nuclear Physics, Lavrentiev ave. 11, Novosibirsk, 630090 Russia
2 Novosibirsk State University, Pirogova st. 2, Novosibirsk, 630090, Russia
3 Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University, Grudziadzka 5, Torun, 87-100 Poland

Реферат: Presently, silicon photomultipliers (SiPMs) are very attractive devices to replace photomultipliers for light detection in many different fields. For example, they could be used in detectors of photons with energies of 20-150 keV for medical and nondestructive testing applications. The small size and high electron gain of SiPMs make them very attractive candidates for pixelated X-ray detectors operating in a photon counting mode. In this research we evaluated the detector performance that can be reached with up-to-date Lu-based scintillators. Application of LYSO:Ce and LFS-3 scintillators provides high count rate capability because of a short scintillator decay time of ∼ 40 ns but enables reaching just a moderate energy resolution. Meanwhile, with a LuYAG:Pr scintillator of quite low non-proportionality one can attain much better energy resolution at a reduced rate. © 2017 IOP Publishing Ltd and Sissa Medialab srl.
Библиографическая ссылка: Kuper K.E. , Oleynikov V.P. , Porosev V.V. , Savinov G.A. , Drozdowski W.
On Reachable Energy Resolution of SiPM Based Scintillation Counters for X-ray Detection
Journal of Instrumentation. 2017. V.12. N1. P01001 :1-14. DOI: 10.1088/1748-0221/12/01/p01001 WOS Scopus РИНЦ CAPlus OpenAlex
Даты:
Поступила в редакцию: 21 июл. 2016 г.
Принята к публикации: 17 дек. 2016 г.
Опубликована в печати: 2 янв. 2017 г.
Опубликована online: 2 янв. 2017 г.
Идентификаторы БД:
Web of science: WOS:000395769600001
Scopus: 2-s2.0-85012040993
РИНЦ: 29480243
Chemical Abstracts: 2018:354691
OpenAlex: W2569720933
Цитирование в БД:
БД Цитирований
Web of science 6
Scopus 6
OpenAlex 7
Альметрики: