Effect of the Thickness of a Poly(1-trimethylsilyl-1-propyne) Film on the Chromatographic Characteristics of a Capillary Column Full article

Journal Russian Journal of Physical Chemistry A
ISSN: 0036-0244 , E-ISSN: 1531-863X
Output data Year: 2021, Volume: 95, Number: 7, Pages: 1484–1490 Pages count : 7 DOI: 10.1134/S0036024421070281
Tags capillary column, poly(1-trimethylsilyl-1-propyne), thermal stability, loading capacity, repeatability index, hydrocarbons, sulfur compounds
Authors Yakovleva E.Yu. 1,2 , Patrushev Yu.V. 1,2
Affiliations
1 Boreskov Institute of Catalysis, Siberian Branch, Russian Academy of Sciences, Novosibirsk, 630090 Russia
2 Novosibirsk State University, Novosibirsk, 630090 Russia

Funding (2)

1 Federal Agency for Scientific Organizations 0303-2016-0001
2 Federal Agency for Scientific Organizations 0303-2016-0008

Abstract: A capillary column is prepared has dimensions of 30 m × 0.53 mm and a 2.82-µm layer of poly(1-trimethylsilyl-1-propyne) (PTMSP). The loading capacity and thermal stability are studied and compared to a commercial Rt-Q-BOND column with dimensions of 30 m × 0.32 mm × 10 µm. It is shown that the loading capacity with respect to ethylbenzene is 160 ng for a column with a PTMSP layer 2.82 µm thick, which is 8 times higher than for an Rt-Q-BOND column with a layer of a poly(divinylbenzene) sorbent 10 µm thick. The separating capacity of the prepared column, calculated for certain pairs of the peaks of the components of the butene–butane fraction, is superior to that of an Rt-Q-BOND column. The macrozone of methane, the fraction of which in the mixture is more than 90%, is selectively separated from the related impurities. A comparative assessment of the repeatability of the retention times of sulfur compounds on the studied column and a commercial column shows satisfactory repeatability, and the relative mean square deviation (RMSD) does not exceed 0.47%.
Cite: Yakovleva E.Y. , Patrushev Y.V.
Effect of the Thickness of a Poly(1-trimethylsilyl-1-propyne) Film on the Chromatographic Characteristics of a Capillary Column
Russian Journal of Physical Chemistry A. 2021. V.95. N7. P.1484–1490. DOI: 10.1134/S0036024421070281 WOS Scopus РИНЦ AN OpenAlex
Original: Яковлева Е.Ю. , Патрушев Ю.В.
Влияние толщины пленки поли(1-триметилсилил-1-пропина) на хроматографические характеристики капиллярной колонки
Журнал физической химии. 2021. Т.95. №7. С.1124-1130. DOI: 10.31857/s0044453721070281 РИНЦ OpenAlex
Dates:
Submitted: Aug 20, 2020
Accepted: Dec 22, 2020
Published print: Jul 15, 2021
Published online: Jul 15, 2021
Identifiers:
Web of science: WOS:000674173200029
Scopus: 2-s2.0-85110514970
Elibrary: 46912426
Chemical Abstracts: 2021:1574716
OpenAlex: W3186322397
Citing:
DB Citing
Scopus 1
Web of science 2
Elibrary 2
OpenAlex 1
Altmetrics: