The Optical Dissector Bunch Length Measurements at the Metrology Light Source Тезисы доклада

Конференция 6th International Beam Instrumentation Conference
20-24 авг. 2017 , Grand Rapids, Michigan
Сборник Proceedings of the 6th International Beam Instrumentation Conference (IBIC2017)
Сборник, JACoW. Geneva, Switzerland.2018. ISBN 978-3-95450-192-2.
Вых. Данные Год: 2017, Страницы: 125 - 128 Страниц : 4 DOI: 10.18429/JACoW-IBIC2017-TU1AB3
Авторы Malyutin D. 1 , Matveenko A. 1 , Ries M. 1 , Anchugov O. 2 , Dorokhov V. 2 , Krutikhin S. 2 , Meshkov O. 2
Организации
1 Helmholtz-Zentrum Berlin, Berlin, Germany
2 Budker Institute of Nuclear Physics, Novosibirsk, Russia

Реферат: The bunch longitudinal profile measurements using an optical dissector are introduced in the paper. The principles of the dissector operation are briefly discussed. The first measurements using the optical dissector at the Metrology Light Source are presented. Results are analyzed and compared with the bunch profiles from the streak camera measurements. Measurement errors and limitations of the both methods are estimated. Possible applications for the presented technique are discussed.
Библиографическая ссылка: Malyutin D. , Matveenko A. , Ries M. , Anchugov O. , Dorokhov V. , Krutikhin S. , Meshkov O.
The Optical Dissector Bunch Length Measurements at the Metrology Light Source
В сборнике Proceedings of the 6th International Beam Instrumentation Conference (IBIC2017). – JACoW., 2017. – Т.6. – C.125 - 128. – ISBN 978-3-95450-192-2. DOI: 10.18429/JACoW-IBIC2017-TU1AB3 Scopus