Sciact
  • EN
  • RU

Magnetic Measurements in Small Aperture of Indirect Cooling Wiggler Full article

Conference International Conference "Synchrotron and Free electron laser Radiation: generation and application"
13-17 Jul 2020 , Novosibirsk
Journal AIP Conference Proceedings
ISSN: 0094-243X , E-ISSN: 1551-7616
Output data Year: 2020, Volume: 2299, Article number : 020012, Pages count : 6 DOI: 10.1063/5.0030374
Authors Khrushchev S. 1 , Kanonik P. 1 , Mezentsev N. 1 , Safronov A. 1 , Shkaruba V. 1 , Tsukanov V. 1 , Volkov A. 1 , Zorin A. 1
Affiliations
1 Budker Institute of Nuclear Physics, pr. Akad. Lavrent’eva 11, 630090, Novosibirsk, Russia

Abstract: Several last superconducting wigglers fabricated at BINP have indirect cooling. They all have a small aperture of cryogenic temperature. This feature makes measurement quite a complicated task. A magnetic measurement system designed especially for one of such wigglers is described in this article. Results of magnetic measurements both with a Hall probe and by the stretched wire method are also presented.
Cite: Khrushchev S. , Kanonik P. , Mezentsev N. , Safronov A. , Shkaruba V. , Tsukanov V. , Volkov A. , Zorin A.
Magnetic Measurements in Small Aperture of Indirect Cooling Wiggler
AIP Conference Proceedings. 2020. V.2299. 020012 :1-6. DOI: 10.1063/5.0030374 Scopus AN OpenAlex
Dates:
Published print: Nov 17, 2020
Identifiers:
Scopus: 2-s2.0-85096503762
Chemical Abstracts: 2021:1074996
OpenAlex: W3105932762
Citing:
DB Citing
Scopus 1
OpenAlex 3
Altmetrics: