Effect of the Nanorough Surface of TiO2 Thin Films on the Compatibility with Endothelial Cells Научная публикация
Журнал |
International Journal of Molecular Sciences
ISSN: 1422-0067 , E-ISSN: 1661-6596 |
||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Вых. Данные | Год: 2023, Том: 24, Номер: 7, Номер статьи : 6699, Страниц : 19 DOI: 10.3390/ijms24076699 | ||||||||||||
Ключевые слова | titanium oxide, titanium oxynitride, thin films, nanoroughness, cytocompatibility, reactive magnetron sputtering | ||||||||||||
Авторы |
|
||||||||||||
Организации |
|
Информация о финансировании (2)
1 | Министерство здравоохранения Росcийской Федерации | 056-00125-21-00 AVRB-2021-0001 (121032300337-5) |
2 | Министерство науки и высшего образования Российской Федерации (с 15 мая 2018) | 075-00707-2200 (122022800132-1) (FWNR-2022-0009) |
Реферат:
The cytocompatibility of titanium oxides (TiO2) and oxynitrides (N-TiO2, TiOxNy) thin films depends heavily on the surface topography. Considering that the initial relief of the substrate and the coating are summed up in the final topography of the surface, it can be expected that the same sputtering modes result in different surface topography if the substrate differs. Here, we investigated the problem by examining 16 groups of samples differing in surface topography; 8 of them were hand-abraded and 8 were machine-polished. Magnetron sputtering was performed in a reaction gas medium with various N2:O2 ratios and bias voltages. Abraded and polished uncoated samples served as controls. The surfaces were studied using atomic force microscopy (AFM). The cytocompatibility of coatings was evaluated in terms of cytotoxicity, adhesion, viability, and NO production. It has been shown that the cytocompatibility of thin films largely depends on the surface nanostructure. Both excessively low and excessively high density of peaks, high and low kurtosis of height distribution (Sku), and low rates of mean summit curvature (Ssc) have a negative effect. Optimal cytocompatibility was demonstrated by abraded surface with a TiOxNy thin film sputtered at N2:O2 = 1:1 and Ub = 0 V. The nanopeaks of this surface had a maximum height, a density of about 0.5 per 1 µm2, Sku from 4 to 5, and an Ssc greater than 0.6. We believe that the excessive sharpness of surface nanostructures formed during magnetron sputtering of TiO2 and N-TiO2 films, especially at a high density of these structures, prevents both adhesion of endothelial cells, and their further proliferation and functioning. This effect is apparently due to damage to the cell membrane. At low height, kurtosis, and peak density, the main factor affecting the cell/surface interface is inefficient cell adhesion.
Библиографическая ссылка:
Zhuravleva I.Y.
, Surovtseva M.A.
, Vaver A.A.
, Suprun E.A.
, Kim I.I.
, Bondarenko N.A.
, Kuzmin O.S.
, Mayorov A.P.
, Poveshchenko O.V.
Effect of the Nanorough Surface of TiO2 Thin Films on the Compatibility with Endothelial Cells
International Journal of Molecular Sciences. 2023. V.24. N7. 6699 :1-19. DOI: 10.3390/ijms24076699 WOS Scopus РИНЦ CAPlus PMID OpenAlex
Effect of the Nanorough Surface of TiO2 Thin Films on the Compatibility with Endothelial Cells
International Journal of Molecular Sciences. 2023. V.24. N7. 6699 :1-19. DOI: 10.3390/ijms24076699 WOS Scopus РИНЦ CAPlus PMID OpenAlex
Даты:
Поступила в редакцию: | 28 февр. 2023 г. |
Принята к публикации: | 30 мар. 2023 г. |
Опубликована в печати: | 3 апр. 2023 г. |
Опубликована online: | 3 апр. 2023 г. |
Идентификаторы БД:
Web of science: | WOS:000970294700001 |
Scopus: | 2-s2.0-85152336913 |
РИНЦ: | 50458681 |
Chemical Abstracts: | 2023:810322 |
PMID (PubMed): | 37047671 |
OpenAlex: | W4362559879 |