Coupling Correction System on the SKIF Light Source and TbT Diagnostics of Linear Difference Resonance with Swing of Eigenmodes Full article
Journal |
Journal of Instrumentation
ISSN: 1748-0221 |
||
---|---|---|---|
Output data | Year: 2025, Volume: 20, Number: 01, Article number : P01010, Pages count : 16 DOI: 10.1088/1748-0221/20/01/p01010 | ||
Tags | Accelerator Applications; Beam Optics; Instrumentation for particle accelerators and storage rings - low energy (linear accelerators, cyclotrons, electrostatic accelerators); Instrumentation for synchrotron radiation accelerators | ||
Authors |
|
||
Affiliations |
|
Funding (2)
1 | Ministry of Science and Higher Education of the Russian Federation | FWUR-2024-0041 |
2 | Russian Science Foundation | 22-12-20025 (122041800053-0) |
Abstract:
The coupling correction system of the future SKIF light source has been optimized with the use of numerical simulation. It includes 128 BPMs (out of 224), 128 skew-quadrupoles out of 256 in MBA sections and 32 skew-quadrupoles in dispersion-free intervals. The system is complementary to the global correction and is intended to suppress simultaneously vertical dispersion and linear difference resonance. High efficiency of the EVD-based correction method has been demonstrated at various numerical examples. The possibility of determining the width of the linear difference resonance, which is necessary for such a correction, by the slope of the ellipses of normal modes is under study. The modes are resonantly swung and their elliptical shape is reproduced according to the TbT (turn-by-turn) data of the BPMs. The results of the corresponding real experiment on VEPP-4M are presented, as well as the numerical experiment on the swing of eigenmodes on the SKIF.
Cite:
Dorokhova D.V.
, Dorokhov V.L.
, Nikitin S.A.
Coupling Correction System on the SKIF Light Source and TbT Diagnostics of Linear Difference Resonance with Swing of Eigenmodes
Journal of Instrumentation. 2025. V.20. N01. P01010 :1-16. DOI: 10.1088/1748-0221/20/01/p01010 Scopus OpenAlex publication_identifier_short.sciact_skif_identifier_type
Coupling Correction System on the SKIF Light Source and TbT Diagnostics of Linear Difference Resonance with Swing of Eigenmodes
Journal of Instrumentation. 2025. V.20. N01. P01010 :1-16. DOI: 10.1088/1748-0221/20/01/p01010 Scopus OpenAlex publication_identifier_short.sciact_skif_identifier_type
Dates:
Submitted: | Oct 1, 2024 |
Accepted: | Dec 13, 2024 |
Published print: | Jan 10, 2025 |
Published online: | Jan 10, 2025 |
Identifiers:
Scopus: | 2-s2.0-85214827543 |
OpenAlex: | W4406242646 |
publication_identifier.sciact_skif_identifier_type: | 3662 |
Citing:
Пока нет цитирований