Functional MRI and NMR Spectroscopy of an Operating Gas–Liquid–Solid Catalytic Reactor Научная публикация

Конференция 7th International Conference on Recent Advances in MR Applications to Porous Media
04-08 июл. 2004 , Palaiseau
Журнал Magnetic Resonance Imaging
ISSN: 0730-725X , E-ISSN: 1873-5894
Вых. Данные Год: 2005, Том: 23, Номер: 2, Страницы: 221-225 Страниц : 5 DOI: 10.1016/j.mri.2004.11.022
Ключевые слова 27Al MRI, Alumina, Gas-liquid-solid reaction, Heterogeneous catalysis, Hydrogenation, NMR thermometry, Nuclear magnetic resonance imaging, α-Methylstyrene
Авторы Koptyug Igor V. 1 , Lysova Anna A. 1 , Kulikov Alexander V. 2 , Kirillov Valery A. 2 , Parmon Valentin N. 2 , Sagdeev Renad Z. 1
Организации
1 International Tomography Center, Novosibirsk 630090, Russia
2 Boreskov Institute of Catalysis, Novosibirsk 630090, Russia

Информация о финансировании (8)

1 Netherlands Organisation for Scientific Research 047.015.006
2 Российский фонд фундаментальных исследований 02-03-32770
3 Российский фонд фундаментальных исследований 03-03-89014
4 Сибирское отделение Российской академии наук 41
5 Сибирское отделение Российской академии наук 166
6 Региональный общественный Фонд содействия отечественной науке
7 Совет по грантам Президента Российской Федерации НШ-2298.2003.3
8 Международный благотворительный научный фонд им. академика К.И. Замараева

Реферат: A dynamic in situ study of α-methylstyrene catalytic hydrogenation on a single catalyst pellet or in a granular bed is performed using 1H MRI and spatially resolved 1H NMR spectroscopy. Owing to reaction exothermicity, a reciprocating motion of the liquid front within the pellet accompanied by pellet temperature oscillations has been observed. Spatially resolved information on the reactant to product conversion within the catalyst bed has been obtained for a steady-state regime. Two-dimensional 27Al NMR images of alumina catalyst supports and other alumina-containing materials have been detected using moderate magnetic field gradients (80 G/cm) and a two-pulse spin-echo sequence. Temperature dependence of signal intensity and 27Al T1 time of alumina are considered as possible temperature sensors for NMR thermometry applications.
Библиографическая ссылка: Koptyug I.V. , Lysova A.A. , Kulikov A.V. , Kirillov V.A. , Parmon V.N. , Sagdeev R.Z.
Functional MRI and NMR Spectroscopy of an Operating Gas–Liquid–Solid Catalytic Reactor
Magnetic Resonance Imaging. 2005. V.23. N2. P.221-225. DOI: 10.1016/j.mri.2004.11.022 WOS Scopus РИНЦ CAPlusCA OpenAlex
Даты:
Опубликована в печати: 1 февр. 2005 г.
Опубликована online: 13 апр. 2005 г.
Идентификаторы БД:
Web of science: WOS:000228658400016
Scopus: 2-s2.0-17044427951
РИНЦ: 13484035
Chemical Abstracts: 2005:319075
Chemical Abstracts (print): 143:80580
OpenAlex: W2039026720
Цитирование в БД:
БД Цитирований
Web of science 5
Scopus 5
РИНЦ 5
OpenAlex 6
Альметрики: