Application of the External Standard Method with a Correction for Absorption in the SRXRF Analysis of Biological Tissue Full article
Journal |
Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques
ISSN: 1027-4510 , E-ISSN: 1819-7094 |
||||||||
---|---|---|---|---|---|---|---|---|---|
Output data | Year: 2015, Volume: 9, Number: 6, Pages: 1164-1167 Pages count : 4 DOI: 10.1134/S1027451015060208 | ||||||||
Tags | international standard specimens, mass attenuation factors, synchrotron radiation, X-ray fluorescence analysis | ||||||||
Authors |
|
||||||||
Affiliations |
|
Funding (2)
1 | Siberian Branch of the Russian Academy of Sciences | |
2 | Russian Science Foundation |
Abstract:
A variant of the analysis of biological tissue (standard liver specimen, NCSZC 85005 Beef liver),
where its reference specimen is q standard specimen of the geological matrix (soil, IAEA Soil7), is consid
ered. Concentrations of elements: K, Ca, Mn, Fe, Cu, Zn, Br, Rb, and Sr in the standard liver specimen are
determined with and without consideration of the absorption of fluorescence emission by different matrices.
The introduction of an absorption correction makes it possible to effectively take into account the difference
in the absorption properties of the matrices under investigation (liver and soil) and determine the concentra
tions of chemical elements, which insignificantly differ from certified data.
Cite:
Trunova V.A.
, Sidorina A.V.
, Zolotarev K.V.
, Kriventsov V.V.
Application of the External Standard Method with a Correction for Absorption in the SRXRF Analysis of Biological Tissue
Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques. 2015. V.9. N6. P.1164-1167. DOI: 10.1134/S1027451015060208 WOS Scopus РИНЦ AN OpenAlex
Application of the External Standard Method with a Correction for Absorption in the SRXRF Analysis of Biological Tissue
Journal of Surface Investigation: X-Ray, Synchrotron and Neutron Techniques. 2015. V.9. N6. P.1164-1167. DOI: 10.1134/S1027451015060208 WOS Scopus РИНЦ AN OpenAlex
Original:
Трунова В.А.
, Сидорина А.В.
, Золотарев К.В.
, Кривенцов В.В.
Использование способа внешнего стандарта с поправкой на поглощение в РФА-СИ анализе биологических тканей
Поверхность. Рентгеновские, синхротронные и нейтронные исследования. 2015. №11. С.50-54. DOI: 10.7868/S0207352815110207 РИНЦ OpenAlex
Использование способа внешнего стандарта с поправкой на поглощение в РФА-СИ анализе биологических тканей
Поверхность. Рентгеновские, синхротронные и нейтронные исследования. 2015. №11. С.50-54. DOI: 10.7868/S0207352815110207 РИНЦ OpenAlex
Dates:
Submitted: | Jan 20, 2015 |
Published print: | Nov 1, 2015 |
Published online: | Dec 6, 2015 |
Identifiers:
Web of science: | WOS:000213962000008 |
Scopus: | 2-s2.0-84948962247 |
Elibrary: | 26920244 |
Chemical Abstracts: | 2015:1962865 |
OpenAlex: | W2322225105 |