Sciact
  • EN
  • RU

Operation and Performance of the ASHIPH Counters at the KEDR Detector Научная публикация

Конференция Frontier detectors for frontier physics : 13th Pisa Meeting on Advanced Detectors
24-30 мая 2015 , La Biodola, Isola d'Elba
Журнал Nuclear Instruments and Methods in Physics Research Section A
ISSN: 0168-9002
Вых. Данные Год: 2016, Том: 824, Страницы: 79-82 Страниц : 4 DOI: 10.1016/j.nima.2015.10.105
Ключевые слова Aerogel, Cherenkov threshold counters, Particle identification
Авторы Barnyakov A.Yu. 1,3 , Barnyakov M.Yu. 1,3 , Bobrovnikov V.S. 1,3 , Buzykaev A.R. 1,3 , Danilyuk A.F. 2,3 , Katcin A.A. 1,3,4 , Kononov S.A. 1,3 , Kravchenko E.A. 1,3 , Kuyanov I.A. 1,3 , Onuchin A.P. 1,3,4 , Ovtin I.V. 1,3,4 , Rodyakin V.A. 1
Организации
1 Budker Institute of Nuclear Physics, Acad. Lavrentiev Prospect 11, Novosibirsk 630090, Russia
2 Boreskov Institute of Catalysis, Acad. Lavrentiev Prospect 5, Novosibirsk 630090, Russia
3 Novosibirsk State University, St. Pirogova 2, Novosibirsk 630090, Russia
4 Novosibirsk State Technical University, Karl Marks Prospect 20, Novosibirsk 630073, Russia

Информация о финансировании (5)

1 Совет по грантам Президента Российской Федерации НШ-2479.2014.2
2 Российский фонд фундаментальных исследований 14-02-31401
3 Российский фонд фундаментальных исследований 14-02-00984
4 Российский фонд фундаментальных исследований 14-02-01011
5 Российский фонд фундаментальных исследований 15-02-03114

Реферат: In 2014 the fully installed ASHIPH (Aerogel, SHifter, PHotomultiplier) system began its operation in the KEDR experiment at the VEPP-4 M e+e−-collider. The system contains 1000 liters of aerogel with refractive index n=1.05 in 160 counters that are arranged in two layers. Cherenkov light collection is preformed by means of wavelength shifters (WLS). 160 Micro-Channel Plate (MCP) PMTs with multialkali photocathode are used as photodetectors. Efficiency of relativistic particles detection was measured with e+e−→e+e− events and cosmic muons. Detection efficiency for under-threshold particles was measured with cosmic muons. From these data π/K-separation of 4σ at the momentum 1.2 GeV/c was obtained.
Библиографическая ссылка: Barnyakov A.Y. , Barnyakov M.Y. , Bobrovnikov V.S. , Buzykaev A.R. , Danilyuk A.F. , Katcin A.A. , Kononov S.A. , Kravchenko E.A. , Kuyanov I.A. , Onuchin A.P. , Ovtin I.V. , Rodyakin V.A.
Operation and Performance of the ASHIPH Counters at the KEDR Detector
Nuclear Instruments and Methods in Physics Research Section A. 2016. V.824. P.79-82. DOI: 10.1016/j.nima.2015.10.105 WOS Scopus РИНЦ CAPlus OpenAlex
Даты:
Опубликована online: 10 нояб. 2015 г.
Опубликована в печати: 11 июл. 2016 г.
Идентификаторы БД:
Web of science: WOS:000375408700029
Scopus: 2-s2.0-84947326656
РИНЦ: 26778631
Chemical Abstracts: 2015:1842297
OpenAlex: W2245936530
Цитирование в БД:
БД Цитирований
Web of science 6
Scopus 6
РИНЦ 9
OpenAlex 7
Альметрики: