Sciact
  • EN
  • RU

Species-Selective Analysis by Microcolumn Multicapillary Gas Chromatography with Inductively Coupled Plasma Mass Spectrometric Detection Научная публикация

Журнал Analytical Chemistry
ISSN: 0003-2700 , E-ISSN: 1520-6882
Вых. Данные Год: 1999, Том: 71, Номер: 20, Страницы: 4534-4543 Страниц : 10 DOI: 10.1021/ac990525d
Ключевые слова Environmental Pollutants; Gas Chromatography-Mass Spectrometry; Indicators and Reagents; chemical analysis; dispersion; gas chromatography; mass spectrometry
Авторы Rodrigueż Isaac 1 , Mounicou Sandra 2 , Łobiński Ryszard 2 , Sidelnikov Vladimir 3 , Patrushev Youri 3 , Yamanaka Michiko 4
Организации
1 Department of Analytical Chemistry, Universidad de Santiago de Compostela, 15706 Santiago, Spain
2 CNRS EP132, He´lioparc, 2, av. Pr. Angot, 64053 Pau-Pyre´ne´es, France
3 Boreskov Institut of Catalysis, Russian Academy of Sciences, Siberian Branch, Pr. Ak. Lavrentieva 5, 630090 Novosibirsk, Russia
4 Application Development Department, Yokogawa Analytical Systems Inc., 2-11-13 Nakacho, Musashino-shi, Tokyo, Japan

Информация о финансировании (2)

1 European Commission SMT4-CT96-2044
2 Xunta Galicia

Реферат: A glass rod (5−20 cm long, 2 mm o.d.) containing more than 1200 parallel microchannels (<40 μm i.d.) was converted into a high-resolution (>100 theoretical plates cm-1) GC column by coating the inside of each channel in a way that compensated for the dispersion of the channel inner diameter. The columns were evaluated for the separation of mixtures of several organometallic (Hg, Sn, Pb) compounds prior to on-line sensitive metal-selective detection by ICPMS. Chromatographic separation conditions were optimized to enable a rapid (within a maximum 30 s) multielemental speciation analysis. Absolute detection limits were 0.1 pg for Hg, 0.05 pg for Sn, and 0.03 pg for Pb using the carrier gas flows of ∼200 mL min-1. The microcolumn multicapillary GC/ICPMS developed was applied to the analysis of a number of environmental samples. The results were validated with certified reference materials for tin (BCR477, PACS-2) and mercury (DORM-1, TORT-1).
Библиографическая ссылка: Rodrigueż I. , Mounicou S. , Łobiński R. , Sidelnikov V. , Patrushev Y. , Yamanaka M.
Species-Selective Analysis by Microcolumn Multicapillary Gas Chromatography with Inductively Coupled Plasma Mass Spectrometric Detection
Analytical Chemistry. 1999. V.71. N20. P.4534-4543. DOI: 10.1021/ac990525d WOS Scopus РИНЦ CAPlusCA OpenAlex
Даты:
Поступила в редакцию: 18 мая 1999 г.
Принята к публикации: 21 июл. 1999 г.
Опубликована online: 18 сент. 1999 г.
Опубликована в печати: 1 окт. 1999 г.
Идентификаторы БД:
Web of science: WOS:000083212400016
Scopus: 2-s2.0-0032726557
РИНЦ: 13306543
Chemical Abstracts: 1999:589051
Chemical Abstracts (print): 131:294804
OpenAlex: W2081174852
Цитирование в БД:
БД Цитирований
Web of science 53
Scopus 63
РИНЦ 56
OpenAlex 57
Альметрики: