Sciact
  • EN
  • RU

The Optical Dissector Bunch Length Measurements at the Metrology Light Source Conference attendances

Language Английский
Participant type Устный
URL https://accelconf.web.cern.ch/ibic2017/talks/tu1ab3_talk.pdf
Conference 6th International Beam Instrumentation Conference
20-24 Aug 2017 , Grand Rapids, Michigan
Authors Malutin Dmitry 1 , Matveenko A. N. 1 , Ries M 1 , Anchugov Oleg V. 2 , Dorokhov Viktor Leonidovich 2 , Krutikhin Sergei Aleksandrovich 2 , Meshkov Oleg Igorevich 2
Affiliations
1 Helmholtz-Centre Berlin for Materials and Energy BESSY
2 Budker Institute of Nuclear Physics SB RAS

Abstract: The bunch longitudinal profile measurements using an optical dissector are introduced in the paper. The principles of the dissector operation are briefly discussed. The first measurements using the optical dissector at the Metrology Light Source are presented. Results are analyzed and compared with the bunch profiles from the streak camera measurements. Measurement errors and limitations of the both methods are estimated. Possible applications for the presented technique are discussed.
Cite: Malutin D. , Matveenko A.N. , Ries M. , Anchugov O.V. , Dorokhov V.L. , Krutikhin S.A. , Meshkov O.I.
The Optical Dissector Bunch Length Measurements at the Metrology Light Source
6th International Beam Instrumentation Conference 20-24 Aug 2017