Sciact
Toggle navigation
  • EN
  • RU

Sections:

  • Articles
  • Books
  • Conference attendances
  • Conference theses
  • Patents

Progress and Perspectives of FARICH R&D for the Super Charm-Tau Factory Project Full article

Common Language: Английский, Genre: Full article,
Status: Published, Source type: Original
Journal Nuclear Instruments and Methods in Physics Research Section A
ISSN: 0168-9002
Output data Year: 2022, Volume: 1039, Article number : 167044, Pages count : 4 DOI: 10.1016/j.nima.2022.167044
Tags Aerogel; RICH; SiPM; PID system
Authors Barnyakov A.Yu. 1,2 , Barnyakov M.Yu. 1,2 , Bobrovnikov V.S. 1,3 , Buzykaev A.R. 1 , Daniluyk A.F. 1,4 , Düren M. 6 , Hayrapetyan A. 6 , Katcin A.A. 1,3 , Kayan H. 5 , Kononov S.A. 1,3 , Kravchenko E.A. 3,1 , Kuyanov I.A. 1 , Ovtin I.O. 1,3 , Podgornov N.A. 1,3 , Pomuleva S.I. 3 , Schmidt M.A. 6 , Shalygin A.S. 4 , Traxler M. 5
Affiliations
1 Budker Institute of Nuclear Physics, Acad. Lavrentiev Prospect 11, 630090, Novosibirsk, Russia
2 Novosibirsk State Technical University, Karl Marks Prospect 20, 630073, Novosibirsk, Russia
3 Novosibirsk State University, St. Pirogova 1, 630090, Novosibirsk, Russia
4 Boreskov Institute of Catalysis, Acad. Lavrentiev Prospect 5, 630090, Novosibirsk, Russia
5 GSI Helmholtzzentrum für Schwerionenforschung GmbH, Planckstraße 1, 64291, Darmstadt, Germany
6 Justus-Liebig-Universität, Ludwigstraße 23, 35390 Gießen, Germany

Funding (1)

1 European Commission 871072 H2020-INFRASUPP CREMLINplus

Abstract: Particle identification system based on Focusing Aerogel RICH (FARICH) detector is considered as an option for the future experiments at the Super Charm-Tau Factory (Russia). We present the progress of FARICH R&D at the Budker Institute of Nuclear Physics. New samples of focusing 4-layer aerogels with maximal refractive index 1.065 were produced in 2020–2021. First beam test results with relativistic electrons demonstrate single photon resolution (SPR) of 910 mrad. According to simulation results, the aerogels with such SPR are able to provide -separation at the level of more than 3 standard deviations for tracks with momentum 1.5 GeV/c. The first version of electronics to readout SiPM arrays based on TDC implemented on FPGA (FPGA-TDC) was developed and manufactured.
Cite: Barnyakov A.Y. , Barnyakov M.Y. , Bobrovnikov V.S. , Buzykaev A.R. , Daniluyk A.F. , Düren M. , Hayrapetyan A. , Katcin A.A. , Kayan H. , Kononov S.A. , Kravchenko E.A. , Kuyanov I.A. , Ovtin I.O. , Podgornov N.A. , Pomuleva S.I. , Schmidt M.A. , Shalygin A.S. , Traxler M.
Progress and Perspectives of FARICH R&D for the Super Charm-Tau Factory Project
Nuclear Instruments and Methods in Physics Research Section A. 2022. V.1039. 167044 :1-4. DOI: 10.1016/j.nima.2022.167044 WOS Scopus РИНЦ
Dates:
Submitted: Apr 14, 2022
Accepted: Jun 21, 2022
Published online: Jun 25, 2022
Published print: Sep 11, 2022
Identifiers:
Web of science WOS:000828158600003
Scopus 2-s2.0-85133461928
Elibrary 49158139
AN 2022:1721153
Altmetrics: