Sciact
  • EN
  • RU

Orthogonality and Quality of GC × GC Separations for Complex Samples with Ionic Liquid Stationary Phases in First Dimension Full article

Journal Chromatographia
ISSN: 0009-5893 , E-ISSN: 1612-1112
Output data Year: 2019, Volume: 82, Number: 2, Pages: 615-624 Pages count : 10 DOI: 10.1007/s10337-018-3672-4
Tags Ionic liquid GC × GC Nearest neighbor distances Chromatographic resolution Orthogonality Separation quality
Authors Shashkov M.V. 1,2 , Sidelnikov V.N. 1,2
Affiliations
1 Boreskov Institute of Catalysis SB RAS, pr. Lavrentieva 5, Novosibirsk 630090, Russia
2 Novosibirsk State University, st. Pyrogova 1, Novosibirsk 630090, Russia

Funding (1)

1 Ministry of Science and Higher Education of the Russian Federation ГЗ-2017-2020

Abstract: In this paper, the advantages of using a pyridinium and imidazolium ionic liquids in the first column for GC×GC separation of complex mixtures—coal pyrolysis product, bio-oil, and essential oil from Pituranthos scoparius—in comparison with polyethylenglycol phase has been demonstrated. The nearest neighbor distance (NND) approach to evaluate the separation quality and orthogonality has been used for the comparison of GC×GC separations for different ionic liquid columns in the first dimension. It was found that they give essentially different results for both the separation quality and orthogonality, evaluated using parameters derived from NND approach. For a mixture of coal pyrolysis products containing only two classes of compounds—phenols and aromatic compounds—the most polar ionic liquid bis4MPyC6 shows nearly the highest orthogonality and separation quality. In the case of separation bio-oil and essential oil, the best orthogonality was demonstrated for the least polar of the tested ionic liquids—bis3.5MPyC9. At the same time, the efficiency of columns exerts a significant effect on the separation quality parameter. As a result, this parameter has the highest value for all mixtures tested using the polyethylene glycol (ZB-WAX) reference phase, which is the less polar from all series, but the most efficient.
Cite: Shashkov M.V. , Sidelnikov V.N.
Orthogonality and Quality of GC × GC Separations for Complex Samples with Ionic Liquid Stationary Phases in First Dimension
Chromatographia. 2019. V.82. N2. P.615-624. DOI: 10.1007/s10337-018-3672-4 WOS Scopus РИНЦ ANCAN OpenAlex
Dates:
Submitted: Jul 30, 2018
Accepted: Dec 4, 2018
Published online: Dec 13, 2018
Published print: Feb 14, 2019
Identifiers:
Web of science: WOS:000460411700012
Scopus: 2-s2.0-85058380799
Elibrary: 38640949
Chemical Abstracts: 2018:2533373
Chemical Abstracts (print): 170:483815
OpenAlex: W2904674198
Citing:
DB Citing
Scopus 7
Web of science 7
Elibrary 8
OpenAlex 9
Altmetrics: