Sciact
  • EN
  • RU

Tests of FARICH Prototype with Precise Photon Position Detection Full article

Conference 8th International Workshop on Ring Imaging Cherenkov Detectors (RICH 2013)
02-06 Dec 2013 , Hayama, Kanagawa
Journal Nuclear Instruments and Methods in Physics Research Section A
ISSN: 0168-9002
Output data Year: 2014, Volume: 766, Pages: 88-91 Pages count : 4 DOI: 10.1016/j.nima.2014.04.086
Tags Aerogel, Cherenkov counter, Particle identification, Ring imaging
Authors Barnyakov A.Yu. 1 , Barnyakov M.Yu. 1,3 , Basok I.Yu. 1 , Blinov V.E. 1,3 , Bobrovnikov V.S. 1 , Borodenko A.A. 1 , Buzykaev A.R. 1 , Danilyuk A.F. 4 , Degenhardt C. 6 , Dorscheid R. 6 , Finogeev D.A. 5 , Frach T. 6 , Gulevich V.V. 1 , Karavicheva T.L. 5 , Kasyanenko P.V. 1 , Kononov S.A. 1,2 , Korda D.V. 1,3 , Kravchenko E.A. 1,2 , Kudryavtsev V.N. 1 , Kurepin A.B. 5 , Kuyanov I.A. 1 , Muelhens O. 6 , Onuchin A.P. 1,3 , Ovtin I.V. 1,3 , Podgornov N.A. 1,3 , Predein A.Yu. 4 , Prisekin V.G. 1 , Protsenko R.S. 4 , Razin V.I. 5 , Reshetin A.I. 5 , Schulze R. 6 , Shekhtman L.I. 1,2 , Talyshev A.A. 1,2 , Usenko E.A. 5 , Zwaans B. 6
Affiliations
1 Budker Institute of Nuclear Physics SB RAS, Novosibirsk, Russia
2 Novosibirsk State University, Novosibirsk, Russia
3 Novosibirsk State Technical University, Novosibirsk, Russia
4 Boreskov Institute of Catalysis SB RAS, Novosibirsk, Russia
5 Institute of Nuclear Research RAS, Moscow, Russia
6 Philips Digital Photon Counting, Aachen, Germany

Funding (2)

1 Siberian Branch of the Russian Academy of Sciences 103
2 The Ministry of Education and Science of the Russian Federation

Abstract: In June 2012 a FARICH prototype from Philips Digital Photon Counting (PDPC) based on a photon camera with dimensions of 200×200 mm has been tested at CERN. Remarkable particle separation has been achieved with a 4-layer aerogel sample: the π /K separation at a 6 GeV/c momentum is 3.5σ , the μ/π separation is 5.3σ at 1 GeV/c. The analysis of the data has shown that the main contribution to the accuracy of the ring radius measurement comes from aerogel. The development of focusing aerogels is proceeding in two main directions: tuning of production technology of multilayer blocks and development of a new production method with continuous density (refractive index) gradient along the block depth. The beam test was carried out in December 2012–January 2013 at the electron beam test facility at the VEPP-4 M e+e− collider. The goal of this test was to measure different single layer and focusing aerogel samples, both multilayer and gradient. Aerogel samples were tested with a PDPC FARICH prototype. A part of DPC SPADs in each pixel was disabled to form an active area of 1×1 mm2. The collected data proved that gradient aerogel samples focus Cherenkov light.
Cite: Barnyakov A.Y. , Barnyakov M.Y. , Basok I.Y. , Blinov V.E. , Bobrovnikov V.S. , Borodenko A.A. , Buzykaev A.R. , Danilyuk A.F. , Degenhardt C. , Dorscheid R. , Finogeev D.A. , Frach T. , Gulevich V.V. , Karavicheva T.L. , Kasyanenko P.V. , Kononov S.A. , Korda D.V. , Kravchenko E.A. , Kudryavtsev V.N. , Kurepin A.B. , Kuyanov I.A. , Muelhens O. , Onuchin A.P. , Ovtin I.V. , Podgornov N.A. , Predein A.Y. , Prisekin V.G. , Protsenko R.S. , Razin V.I. , Reshetin A.I. , Schulze R. , Shekhtman L.I. , Talyshev A.A. , Usenko E.A. , Zwaans B.
Tests of FARICH Prototype with Precise Photon Position Detection
Nuclear Instruments and Methods in Physics Research Section A. 2014. V.766. P.88-91. DOI: 10.1016/j.nima.2014.04.086 WOS Scopus РИНЦ AN OpenAlex
Dates:
Published online: May 14, 2014
Published print: Dec 1, 2014
Identifiers:
Web of science: WOS:000344622200021
Scopus: 2-s2.0-84910035416
Elibrary: 24002414
Chemical Abstracts: 2014:972031
OpenAlex: W2078919215
Citing:
DB Citing
Web of science 7
Scopus 10
Elibrary 8
OpenAlex 10
Altmetrics: