Development of Aerogel Cherenkov Detectors at Novosibirsk Научная публикация

Конференция 5th International Workshop on Ring Imaging Detectors
30 нояб. - 5 дек. 2004 , Playa de Carmen, Yucatan Peninsula
Журнал Nuclear Instruments and Methods in Physics Research Section A
ISSN: 0168-9002
Вых. Данные Год: 2005, Том: 553, Номер: 1-2, Страницы: 125-129 Страниц : 5 DOI: 10.1016/j.nima.2005.08.048
Ключевые слова Aerogel, Cherenkov counters
Авторы Barnyakov A.Yu. 1 , Barnyakov M.Yu. 1 , Bähr J. 2 , Bellunato T. 3 , Beloborodov K.I. 1 , Bobrovnikov V.S. 1 , Buzykaev A.R. 1 , Calvi M. 3 , Danilyuk A.F. 4 , Djordjadze V. 2 , Golubev V.B. 1 , Kononov S.A. 1 , Kravchenko E.A. 1 , Lipka D. 2 , Matteuzzi C. 3 , Musy M. 3 , Onuchin A.P. 1 , Perego D. 3 , Rodyakin V.A. 1 , Savinov G.A. 1 , Serednyakov S.I. 1 , Shamov A.G. 1 , Stephan F. 2 , Tayursky V.A. 1 , Vorobiov A.I. 1
Организации
1 Budker Institute of Nuclear Physics, Novosibirsk, Russia
2 DESY Zeuthen, Zeuthen, Germany
3 Università di Milano-Bicocca and INFN, Milano, Italy
4 Boreskov Institute of Catalysis, Novosibirsk, Russia

Информация о финансировании (3)

1 Российский фонд фундаментальных исследований 02-02-16321
2 Российский фонд фундаментальных исследований 02-02-17321
3 International Association for the Promotion of Co-operation with Scientists from the New Independent States of the Former Soviet Union 03-52-5579

Реферат: The development of aerogel Cherenkov counters with the light collection using a wavelength shifter is described. 80 counters of this type are working in the KEDR detector. A project of similar counters for the SND detector based on “heavy” aerogel with n=1.13 has been developed. Aerogel with a refractive index of 1.006–1.13 and dimensions of blocks up to View the MathML source is produced by the Novosibirsk group for use in Cherenkov counters of different types. The Novosibirsk group is participating in the development of LHCb RICH as well as a beam diagnostics for a photo-injector test facility at DESY–Zeuthen. Recently we started development of RICH based on focusing aerogel (FARICH) for the endcap of the SuperBaBar. For the first time in the world the focusing aerogel with layers of different refractive indices has been produced.
Библиографическая ссылка: Barnyakov A.Y. , Barnyakov M.Y. , Bähr J. , Bellunato T. , Beloborodov K.I. , Bobrovnikov V.S. , Buzykaev A.R. , Calvi M. , Danilyuk A.F. , Djordjadze V. , Golubev V.B. , Kononov S.A. , Kravchenko E.A. , Lipka D. , Matteuzzi C. , Musy M. , Onuchin A.P. , Perego D. , Rodyakin V.A. , Savinov G.A. , Serednyakov S.I. , Shamov A.G. , Stephan F. , Tayursky V.A. , Vorobiov A.I.
Development of Aerogel Cherenkov Detectors at Novosibirsk
Nuclear Instruments and Methods in Physics Research Section A. 2005. V.553. N1-2. P.125-129. DOI: 10.1016/j.nima.2005.08.048 WOS Scopus РИНЦ CAPlusCA OpenAlex
Даты:
Опубликована online: 30 авг. 2005 г.
Опубликована в печати: 11 нояб. 2005 г.
Идентификаторы БД:
Web of science: WOS:000233314900021
Scopus: 2-s2.0-27644587032
РИНЦ: 13495750
Chemical Abstracts: 2005:1154918
Chemical Abstracts (print): 144:158593
OpenAlex: W2157666592
Цитирование в БД:
БД Цитирований
Web of science 16
Scopus 19
РИНЦ 18
OpenAlex 18
Альметрики: