Sciact
  • EN
  • RU

Influence of X-Ray Beam Spatial Coherence on the Diffuse Scattering from Multilayer Mirrors Научная публикация

Журнал Journal of Applied Physics
ISSN: 0021-8979 , E-ISSN: 1089-7550
Вых. Данные Год: 2002, Том: 92, Номер: 12, Страницы: 7593-7598 Страниц : 6 DOI: 10.1063/1.1518131
Ключевые слова Coherent light; Mirrors; Multilayers; Synchrotron radiation; Vectors; X ray diffraction
Авторы Chernov V.A. 1,2 , Kondratiev V.I. 2 , Kovalenko N.V. 2 , Mytnichenko S.V. 2,3 , Zolotarev K.V. 2,3
Организации
1 Institute of Catalysis, Novosibirsk, Russia
2 Siberian Synchrotron Radiation Center, Budker Institute of Nuclear Physics, 11 Lavrentiev Prospect, Novosibirsk, Russia
3 Institute of Solid State Chemistry, Novosibirsk, Russia

Информация о финансировании (2)

1 Российский фонд фундаментальных исследований 00-02-17624
2 Российский фонд фундаментальных исследований 99-02-16671

Реферат: The improved spatial coherence of a synchrotron radiation beam was shown experimentally to stimulate additional diffuse scattering of x rays diffracted from x-ray multilayer mirrors. Although the large-scale (tens of microns) roughness does not affect Bragg diffraction from multilayers, its presence causes phase shifts at the wave packet front. This leads to partial decay of the coherent wave packet and creates additional diffuse scattering. Additional scattering from this mechanism was observed at angles of incidence corresponding to the Bragg and Kiessig maximum angles. The properties of this scattering caused by large-scale roughness, observed due to improved x-ray beam spatial coherence, were shown experimentally to be different from those of diffuse scattering previously reported when the incoming or outgoing angle is equal to the Bragg angle. Typical breaks in the diffuse scattering intensity due to the standing-wave effect are absent, and there is obvious asymmetry of the diffuse scattering cross section around the incoming and outgoing angles. Due to the small angle of incidence, the coherently irradiated area has very different dimensions parallel and perpendicular to the beam, which leads to the observed scattering being concentrated in the specular diffraction plane defined by the incident and reflected wave vectors.
Библиографическая ссылка: Chernov V.A. , Kondratiev V.I. , Kovalenko N.V. , Mytnichenko S.V. , Zolotarev K.V.
Influence of X-Ray Beam Spatial Coherence on the Diffuse Scattering from Multilayer Mirrors
Journal of Applied Physics. 2002. V.92. N12. P.7593-7598. DOI: 10.1063/1.1518131 WOS Scopus РИНЦ CAPlus OpenAlex
Даты:
Поступила в редакцию: 2 апр. 2002 г.
Принята к публикации: 10 сент. 2002 г.
Опубликована в печати: 15 дек. 2002 г.
Идентификаторы БД:
Web of science: WOS:000179495100102
Scopus: 2-s2.0-0037115448
РИНЦ: 13404066
Chemical Abstracts: 2002:915355
OpenAlex: W2039601870
Цитирование в БД:
БД Цитирований
Web of science 6
Scopus 5
OpenAlex 7
Альметрики: