Rapid Lung Ventilation MRI Using Parahydrogen-Induced Polarization of Propane Gas Научная публикация
Журнал |
Analyst
ISSN: 0003-2654 , E-ISSN: 1364-5528 |
||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Вых. Данные | Год: 2024, DOI: 10.1039/d4an01029a | ||||||||||||
Ключевые слова | Induced polarization logging; Lung cancer; Nuclear magnetic resonance; Spin polarization | ||||||||||||
Авторы |
|
||||||||||||
Организации |
|
Информация о финансировании (9)
1 | Министерство науки и высшего образования Российской Федерации (с 15 мая 2018) | FWUR-2024-0032 |
2 | Российский научный фонд | 23-23-00394 |
3 | National Institutes of Health | R01NS130258 |
4 | National Institutes of Health | R01NS117146 |
5 | National Institutes of Health | R01NS114972 |
6 | National Heart Lung and Blood Institute | 1F32HL160108 |
7 | National Institutes of Health | 1R21HL154032-01 |
8 | United States Department of Defense | W81XWH-20-10578 |
9 | United States Department of Defense | W81XWH-20-10576 |
Реферат:
Proton-hyperpolarized contrast agents are attractive because they can be imaged on virtually any clinical MRI scanner, which is typically equipped to scan only protons rather than heteronuclei (i.e., anything besides protons, e.g., 13C, 15N, 129Xe, 23Na, etc.). Even though the lifetime of the proton spin hyperpolarization is only a few seconds, it is sufficient for inhalation and scanning of proton-hyperpolarized gas media. We demonstrate the utility of producing hyperpolarized propane gas via heterogeneous parahydrogen-induced polarization for the purpose of ventilation imaging in an excised rabbit lung model. The magnetization of protons in hyperpolarized propane gas is similar to that of tissue water protons, making it possible to rapidly perform lung ventilation imaging with a 0.35 T clinical MRI scanner. Here, we demonstrate the feasibility of rapid (2 s) lung ventilation MRI in excised rabbit lungs using hyperpolarized propane gas with a 1 × 1 mm2 pixel size using a 50 mm slice thickness, and a 1.7 × 1.7 mm2 pixel size using a 9 mm slice thickness.
Библиографическая ссылка:
Chowdhury M.R.H.
, Oladun C.
, Ariyasingha N.M.
, Samoilenko A.
, Bawardi T.
, Burueva D.B.
, Salnikov O.G.
, Kovtunova L.M.
, Bukhtiyarov V.I.
, Shi Z.
, Luo K.
, Tan S.
, Gelovani J.G.
, Koptyug I.V.
, Goodson B.M.
, Chekmenev E.Y.
Rapid Lung Ventilation MRI Using Parahydrogen-Induced Polarization of Propane Gas
Analyst. 2024. DOI: 10.1039/d4an01029a WOS Scopus
Rapid Lung Ventilation MRI Using Parahydrogen-Induced Polarization of Propane Gas
Analyst. 2024. DOI: 10.1039/d4an01029a WOS Scopus
Даты:
Поступила в редакцию: | 29 июл. 2024 г. |
Принята к публикации: | 22 окт. 2024 г. |
Опубликована online: | 12 нояб. 2024 г. |
Идентификаторы БД:
Web of science: | WOS:001352287100001 |
Scopus: | 2-s2.0-85208809841 |
Цитирование в БД:
Пока нет цитирований